OVERVIEW

Revolutionary SX8R Series Bus Coupler Module

The new SX8R Series Bus Coupler Module is designed to revolutionize remote I/O solutions, offering unparalleled flexibility and performance. It supports multiple protocols for seamless integration with diverse systems. Customers can choose from over 40 existing IDEC FC6A MicroSmart PLC I/O modules, supporting a wide range of discrete and analog signals. Expand up to 15 modules (480 discrete points, 120 analog inputs, and 60 analog outputs), while the maximum number of SX8R nodes capacity varying by host unit and protocol. The user-friendly configuration tool saves all settings, eliminating the need for repeated configurations. Additionally, the SX8R Series operates reliably within a broad temperature range of -25°C to 65°C, ensuring robust performance in various environments. Built for endurance, the SX8R is backed by an industry-leading three-year warranty.

APPLICATIONS

Industry Solutions

Wastewater Treatment

Food / Packaging Machinery

Conveyor Equipment / Conveyor

HVAC(air conditioning control, chiller market)

Machine Tools

Irrigation and Agriculture

Key Features

Network Compatibility

With support for EtherNet/IP, Modbus TCP, and CC-Link IE Field Basic, our Bus Coupler offers unparalleled flexibility and compatibility with various industrial protocols. 

Extensive I/O Module Selection

Choose from a wide array of IDEC FC6A MicroSmart PLC I/O modules to customize your system according to specific application requirements, enhancing both functionality and scalability.

Modular Design

Built with a modular architecture, our system allows for easy scalability and customization to meet the specific needs of your application. Expand your I/O capacity effortlessly as your operations grow. 

Quick and Easy Wiring

The Push-In Terminal significantly reduces wiring and maintenance time, offering a fast and straightforward installation process without the need for specialized tools. 

Wide Operating Temperature

Designed to perform in extreme conditions, the Bus Coupler operates efficiently in temperatures ranging from -20 to 65 ˚C, making it ideal for a variety of industrial environments. 

Industry-Leading Warranty

Backed by a 3-year warranty, our Bus Coupler guarantees long-term reliability and peace of mind, underscoring our commitment to quality and customer satisfaction.

User-Friendly Configuration Tool

Simplify setup and maintenance with our intuitive configuration tool, designed to streamline the process and reduce downtime. 

Global Safety Standards

Class I Div 2, CE,  UKCA, UL/cUL approved and RCM certified for global usage.

KEY FEATURES

Remote I/O system using Industrial Ethernet

Remote I/O systems reduce maintenance time, wiring materials, and cable laying in distributed control, as well as decrease the total cost by downsizing the control panel.

The impact of signal weakening and background noise caused by long-distance transmission is minimized. 

SX8R-English Catalog (1)
KEY FEATURES

Compatible with major open networks

Supports EtherNet/IP (adapter), Modbus TCP (server), CC-Link IE Basic (slave station)

SX8R-img04
EP1824-0-SX8R-1
EP1824-0-SX8R copy
KEY FEATURES

Simultaneous Communication with Two Master Stations

A controller and monitoring device can be connected at the same time, even on different networks. You can build a control and monitoring system with a single remote I/O coupler.

 

KEY FEATURES

Build a system with flexible I/O modules

Paired with IDEC's MicroSmart FC6A I/O modules, it facilitates the seamless creation of a remote I/O system. A wide variety of MicroSmart FC6A I/O modules (48 models) can be used to build an efficient remote I/O system.

 

Digital input module

8 models

 

8, 16, 32 points

Digital output module

16 models

Tr. sync / Tr. source / Relay

8, 16, 32 points

Digital mixed I/O module

4 models

Relay

8, 24 points

Analog input module

8 models

Voltage/Current / Thermocouple / RTD

2, 4, 8 points

Analog output module

4 models

Voltage/Current

2, 4 points

Analog I/O module

4 models

Voltage / Current / Thermocouple / RTD

3, 6 points

Temperature sensor input module

4 models

Thermocouple / Thermistor

4, 8 points

SX8R-US (10)
KEY FEATURES

Connect up to 15 I/O modules

Maximum of 7 I/O modules can be connected.

Additional 8 expansion modules can be connected by installing the expansion interface module.

SX8R-English Catalog (3)
KEY FEATURES

For various applications with a wide temperature range
Secure and reliable hardware

SX8R-US (9)

Wide Operating Temperature Range

Suitable for use in hot and cold environments ranging from -25°C to +65°C.

SX8R-img05-EN

I/O Module

Wide range of IDEC MicroSmart FC6A modules compliant with various safety standards. Various relay modules also available.

SX8R-English Catalog (2)

Baseless Structure

Minimal space is needed as no base unit installation is required. I/O modules can be added after installation, enabling flexibility.

RESOURCES

Access Resources and Documents Available

CATALOG

Remote I/O System

Develop Robust Remote I/O Systems Using Our  Wide Range of I/O Modules

DATASHEET

SX8R Bus Coupler Module: Technical Guide

A detailed overview of the SX8R Bus Coupler Module, covering features, specifications, system configurations, and installation guidelines for efficient remote I/O integration in industrial automation.

TECHNICAL ARTICLE

Choosing the Right
Networked Remote I/O Solution

Flexible remote I/O bus coupler supporting multiple Ethernet protocols.

software-EN-2
RESOURCES

Easy configuration and monitoring with a dedicated software

SX8R-img14.png

The dedicated PC configuration tool "SX8R Configurator" (free) is available for configuring communication and module settings. Drag and drop functionality allows easy configuration of I/O modules.
The ON/OFF status of digital I/O modules and the current values, set values, and error information of analog I/O modules can be monitored remotely.

OS: Windows 11, Windows 10
CPU: 1.0GHz or higher
Memory: 2GB or higher
Environment: Microsoft.NET 6.0 or later

 

RESOURCES

Part Numbers

Quantity: 1

 

 

Terminal

Power

Communication protocol

Part No.

Ethernet port 1

Ethernet port 2

SX8R-img16

 

Push-in

24V DC

Modbus TCP communication (server)

EtherNet/IP communication (adapter)

CC-Link IE Field Basic communication (slave station)

Maintenance communication (server)

Maintenance communication (server)

SX8R-ECB4

Screw

SX8R-ECB1