Skip to main content
en-HT3P-sol01-top

 

OVERVIEW

To replace the teaching pendant

Cost reduction by replacing the dedicated terminal with a commercial tablet

 

KEY FEATURES

Reduction of development man-hours

Teaching pendants and self-developed operation terminals tend to be difficult to operate for those who are not accustomed to handling them because they have many buttons and are complicated to operate. Recently, there are voices saying that they want to use commercially available tablets, which are becoming popular in industrial fields, for teaching robots, and that is also the trend. However, even if the world becomes such a trend, safety functions such as emergency stop switches and enable switches will still be required.

en-HT3P-sol01-01-1
en-HT3P-sol02-02

KEY FEATURES

Use your tablet as a robot teaching

With Safety Commander ™ recommended by IDEC, you can use a commercially available tablet as a teaching pendant. By introducing a commercially available tablet, it is not necessary to develop hardware or manage manufacturing in-house, which leads to a reduction in development man-hours. It also makes it easier to respond to parts abolition and market trends.

How about safety?

From the viewpoint of ISO / IEC safety standards, when operating equipment including tablets is used near the hazards of the machine, emergency stop pushbutton switches and enable switches should be used so that the machine can be stopped immediately. Installation of safety equipment is required.
The safety commander has an ergonomic grip structure and an arrangement of enable switches, which makes it easy to hold and operate regardless of the dominant hand. Tablet operation while pressing the enable switch (OFF⇒ON⇒OFF / 3-position operation for ergonomic danger avoidance) and emergency stop in an emergency (equipped with safety lock, safety potential, and direct opening operation function) This is a great advantage because the operation maintains the safety as before.

HT3P-brochurethmb

CATALOG

HT3P Series Safety Commander™ Product Catalog

Discover additional information about the HT3P Series Safety Commander™ within this catalog.

us-HT3P-future05

TECHNICAL ARTICLE

Get a Grip on Industrial Mobile Devices.

Modern consumer-grade tablets can provide a flexible and capable automation HMI experience, but only when used with the right specialized component to safely integrate them into the industrial environment.

 

LINEUP

HT3P-goods-image

HT3P Safety Commander™

The Safety Commander™ makes it easy to hold a tablet securely in an industrial setting, for applications like machinery, robotics, automatic guided vehicles (AGVs), and production lines.

SafetyCommanderKit-HT3P

HT3P Safety Commander™ Starter Kit

KIT-HT3P provides the complete offer for customers seeking to evaluate the Safety Commander™ solutions as the potential replacement of teaching pendants or control panels on the factory floor.

 

Frequently Asked Questions

What accessories are included in the Safety Commander™?

The following maintenance parts are included.

  • Hand strap (HT9Z-3PS1)
  • Telescopic lock release key (HT9Z-3PK01)
  • Sponge sheet for thickness adjustment (HT9Z-3PHA04)
What are the dimensions of the tablet that fits in the Safety Commander™?
Tablet diagonal length: 240~300mm (Screen sizes of 8 to 11 inches)
Are there any restrictions on thickness?

Standard: ~10mm
If the tablet is too thin, please use the included thickness adjustment sponge sheet that comes as standard accessory.
If the tablet thickness is between 11mm and 18mm, please use HT9Z-3PHB08. if the tablet thickness is between 19mm and 24mm, please use HT9Z-3PHB14.

Is it possible for the user to replace the switch, enable, etc.?
The e-stop or enable switch cannot be replaced at customers end.
Is it possible to customize the emergency stop and enable?
Please contact one of our sales representative for customizations.
Is it possible to use it outdoors?
Specifications of this product are for indoor use.
What is the recommended model for connecting with safety relay modules?
The recommended safety relay module is our HR5S, HR6S Series.
Does USB C support data transfer?
No, it is for charging purpose only.
Does is support wired/wireless communication?

Emergency stop and enable SW are not supported by wireless.
The safety devices are wired, and only the tablet is configured to communicate via WIFI.